Another counter to watch when the %Disk Time exceeds 60 percent to 80 percent is the Avg. Disk sec/Transfer. This counter measures the time in seconds of the average disk transfer (i.e., the time the disk needs to service each request). A disk can complete only so much work before its service begins to degrade. When disk performance begins to degrade, the Avg. Disk sec/Transfer increases dramatically. This increase affects NT's overall performance.

You will want to review the Disk Transfers/sec counter to determine the amount of work a disk is completing. This counter measures the rate of read and write operations (also known as the rate of input/output per second) on the selected disk. The amount of work a disk can support depends on the disk technology and the I/O workload the disk encounters. In my experience, an Ultra Fast/Wide SCSI 7200rpm disk encountering a mixed I/O workload (random, sequential, write, and read operations) supports approximately 50 disk transfers per second to 100 disk transfers per second before its performance degrades. Monitoring the Avg. Disk sec/
Transfer counter lets you observe this performance degradation.

Detecting RAID Bottlenecks
RAID technology lets you group multiple hard disks and present them to NT as one logical disk device. To detect a RAID bottleneck, you use the single-disk bottleneck detection techniques I just described, but with a twist. The %Disk Time counter uncovers problems that are brewing in any RAID device. When you're attempting to detect a RAID bottleneck, RAID 0, disk striped sets, is the easiest RAID level to work with. RAID 0 takes advantage of all the disks in the array equally. Thus, a three-disk RAID 0 array can support three times as much workload (i.e., disk requests) and three times as many outstanding disk requests (Avg. Disk Queue Length) as a one-disk configuration before becoming a bottleneck.

In a RAID 1 mirror with two disks, the array uses both disks for all write activities. To determine the workload that a RAID 1 mirror can support (i.e., the number of transfers per second), use the following equation: (disk reads/sec + [2 * disk writes/sec])/(number of disks in the RAID array). Today's RAID 1 mirrors use a two-disk configuration. Despite greater availability, RAID 1 arrays support a slightly lower workload in a write-intensive environment than systems with one hard disk. However, if your Avg. Disk Queue Length divided by the number of disks in the array exceeds 2, you have a serious bottleneck in a RAID 1 mirror.

The RAID 5 disk stripe with parity environment is similar to a RAID 0 stripe set for read-intensive environments. A RAID 5 array with five disks supports almost five times as much workload and up to five times as many outstanding disk requests as a one-disk system before becoming a bottleneck. To calculate how many disk requests a RAID 5 array can support, use the following formula: (disk reads/sec + [4 * disk writes/sec])/(number of disks in the RAID array). A RAID 5 array's performance is different than a RAID 0 stripe set's performance because of additional disk activity associated with parity generation. In a RAID 5 array, parity information is spread across all the disks in the array for fault tolerance. To calculate this parity information, each RAID 5 write operation reads the data block, reads the parity block, logically exclusive Ors (XORs) the data, writes the data block, writes the parity block, and so on for each single write operation. Thus, each write request in a RAID 5 array incurs four disk operations. This parity generation slows write operations in RAID 5 environments compared with RAID 0. However, this parity information lets you continue operations if one of the disks in the RAID 5 array fails. You can replace the failed disk and reconstruct the failed disk's data on the new disk using parity information from the other disks in the array.

You can use hardware-based RAID solutions to avoid the performance pitfall associated with generating this parity information. Hardware-based RAID controllers generate parity information using their own CPU, not the system's CPU. As a result, a system using a hardware-based RAID solution can handle more disk I/O operations than a software-based solution. An additional benefit of offloading parity generation to a hardware-based RAID solution is that you can recover and use processing power elsewhere on your system that might otherwise be wasted on disk I/O parity.

Sizing Additional Disk Capacity for RAID Arrays
If you evaluate your RAID array's performance and determine that the array is causing a bottleneck in your system, you can intelligently size additional storage capacity. Without the information that the Performance Monitor counters provide, you can only guess how much disk space you need to add to improve performance.

Adding a RAID-based disk subsystem to NT can improve a system's performance, availability, and manageability. However, you need to consider fault-
tolerant support, cost, capacity, and performance when sizing RAID subsystems.

Prev. page     1 [2] 3     next page